loading
Office Open Mon-Fri 9am-5pm
Luxury Bathrooms & Spares Experts
Bathroom Spares Experts
Contact Cart
Crosswater CA43-29 Thermostatic Cartridge
Crosswater CA43-29 Thermostatic CartridgeCrosswater Thermostatic CartridgeVernet CA43-29 Thermostatic CartridgeKai Central Essence Wisp Thermostatic CartridgeCrosswater Kelly Hoppen Belgravia Thermo CartridgeCrosswater CA43-29Crosswater CA43-29 Installation

Thermostatic Cartridge for Crosswater CA43-29 KL4000RC Kelly Hoppen | Belgravia | Kai | Wisp

Part Number: CA43-29

SALE: £65.83

You save: £24.12 (27%)
Price includes VAT
Quantity:  
ADD TO BASKET
IN STOCK
Wrong Item? Click to see More
UK Lowest Price Guaranteed
Next Day Delivery Available
Product description

SUMMARY

This is a KL4000RC thermostatic cartridge for Crosswater CA43-29 which is used on the Kelly Hoppen, Belgravia, Design, Kai, Central, Wisp, Essence WLBP1500R, and Atoll Crosswater ranges. This is a genuine Vernet CA43-29 thermostatic cartridge.


About the Crosswater CA43-29 Shower Spares


Cartridge Compatibility: Crosswater
Spare Part: Thermostatic Cartridge CA43-29
Installation: Push-Fit
Colour: White

The CA43-29 is compatible with recessed shower valves by Crosswater post-2013.

The cartridge measures:
- 120.50mm in total length
- 34.45mm at its widest point

*Please see the last two photos in the gallery above for the exploded diagram and Crosswater CA43-29 cartridge removal guide.

Please ensure this is the correct cartridge you need. Take a look at our guide to thermostatic cartridges or please contact us and we will identify the cartridge which you need.


The Thermostatic Cartridge CA43-29 for Crosswater valves will be dispatched on the same working day when ordered before 3:00 PM.


We have a number of Crosswater shower spare parts in stock.


Crosswater CA43-29 Compatibility


The CA43-29 is used on the following Crosswater ranges and models of shower valve mixers:

KELLY HOPPEN KH ZERO 1
- KH01_1000RC I THERMO VALVE
- KH01_1500RC I THERMO VALVE
- KH01_2500RC I THERMO VALVE
- KH01_2000RC I THERMO SHOWER VALVE
- KH02_1000RC I THERMO SHOWER VALVE
- KH02_1501RC I THERMO SHOWER VALVE
- KH02_1500RC I THERMO SHOWER VALVE
- KH02_2000RC I THERMO SHOWER VALVE
- KH02_3000RC I THERMO SHOWER VALVE
- KH03_2000RC I THERMO SHOWER VALVE
- KH03_3000RC I THERMO SHOWER VALVE
- KH03_1000RC I THERMO VALVE
- KH03_1500RC I THERMO VALVE
- KH01_1501RC I THERMO SHOWER VALVE

Belgravia Shower Valves
- BL1000RC+ I THERMO SHOWER VALVE
- BL1500RC+ I THERMO SHOWER VALVE
- BL1000RC_LV+ I THERMO SHOWER VALVE
- BL1500RC_LV+ I THERMO SHOWER VALVE
- BL2500RC+ I THERMO SHOWER VALVE
- BL2000RC+ I THERMO SHOWER VALVE
- BL2000RC_LV+ I THERMO SHOWER VALVE
- BL3000RC+ I THERMO SHOWER VALVE
- BL3000RC_LV+ I THERMO SHOWER VALVE

DESIGN / KAI LEVER TAPS
- KL1000RC I KAI LEVER THERMO SHOWER VALVE

CENTRAL / WISP TAPS
- CE1501RC I CENTRAL THERMO SHOWER VALVE
- WP1000RC I WISP THERMO SHOWER VALVE
- WLBP1500R+

ESSENCE / ATOLL TAPS
- ES1000RC I ESSENCE THERMO SHOWER VALVE
- KH03_1000RC I KH03 THERMO VALVE
- CROSSWATER-PARENT-3

Mike Pro
- PRO1701R
- WLBP1501R
- WP1701R
- US-PRO1701, US-WP1701

What Can Cause a CA43-29 Thermostatic Cartridge to Produce Imprecise Water Temperature Regulation?


Thermostatic cartridges are designed to control water temperature with exactness as calibrated by the shower user. However, a number of factors can lead to an incorrect temperature output such as an inconsistent hot or cold water supply, an blockage in the gauzing from hard water debris or dirt, a cracked cartridge, or a failed thermostat capsule.

Another cause of off the base water temperature control is the “overturning” of the CA43-29 Crosswater compatible thermostatic cartridge. Overturning occurs when the cartridge was turned more than 720 degrees clockwise (upwards two full turns). In this case, the o-ring responsible for anti-scalding might have detached from the cartridge, triggering the absence of temperature control.

To ensure that the CA43-29 cartridge for Crosswater is working as intended and water temperature is properly regulated, check the consistency of both water supplies. If the supplies are normal, isolate both hot and cold water supplies to remove the cartridge from the valve housing. Inspect the gauzing for any residue that can hinder water flow. Remove the residue if it is present. If the gauzing is clear, check to see if there are cracks on the cartridge itself. A cracked cartridge will call for a need to replace the whole cartridge.

If the anti-scald o-ring has come off, remove the Crosswater CA43-29 cartridge and reposition the o-ring on the top of part of the cartridge.
shipping & Returns

FAST DELIVERY

  • Delivery of this item is priced as a 'small' packet. UK delivery costs £5.95.
  • For all in-stock spare parts the typical UK delivery timescale is 2-5 working days.
  • If you need a part urgently then we can provide a next-day (delivered Mon-Fri) UK delivery service for all in-stock small parcels ordered before 3.30pm, Monday - Friday.
  • Next day delivery is available to select at an additional charge during the checkout.
  • We delivery WORLDWIDE. For more information about international deliveries, read our delivery page.

RETURNS

  • If you need to return a part then please telephone Di Vapor on 0121 705 0866 with the reasons for the return within 14 days of receiving the goods.
  • For more information please see our terms and conditions.
Payment & Security

Payment Methods

Di Vapor accepts the following payments methods:

  • Visa
  • Mastercard
  • Paypal
  • Maestro
  • American Express (via PayPal guest checkout only)
  • Cheque (must be cleared before dispatch)
  • BACS

SECURITY

Di Vapor treats your privacy and security with the utmost importance. The payment systems used by Di Vapor are based on industry standards to ensure all payments are securely handled. In fact, we ensure the Di Vapor website is regularly checked to guarantee compliance to PCI security standards.

Related items you may need